Qauv Tso Tawm Reagent

Lus piav qhia luv luv:

Cov khoom siv no muaj feem xyuam rau kev kho tus qauv ua ntej los kuaj, kom yooj yim rau kev siv cov tshuaj hauv vitro diagnostic reagents lossis cov cuab yeej los ntsuas qhov ntsuas.


Product Detail

Khoom cim npe

Khoom npe

Macro & Micro-Test Sample Tso Reagent

Daim ntawv pov thawj

CE, FDA, NMPA

Cov khoom tseem ceeb

Lub npe Cov khoom tseem ceeb Cheebtsamspecifications Ntau
Qauv tso tawmreagent Dithiothreitol, sodium dodecylsulfate (SDS), RNase inhibitor,surfactant, purified dej 0.5 mL/Vial 50 Vial

Lus Cim: Cov khoom siv hauv cov khoom siv sib txawv ntawm cov khoom siv tsis sib hloov.

Cia tej yam kev mob thiab txee lub neej

Khaws thiab thauj ntawm chav tsev kub.Lub neej txee yog 24 lub hlis.

Cov cuab yeej siv tau

Cov cuab yeej thiab cov khoom siv thaum lub sij hawm ua qauv, xws li pipettes, vortex mixers,da dej, thiab lwm yam.

Cov qauv xav tau

Freshly sau oropharyngeal swabs, nasopharyngeal swabs.

Precision

Thaum cov khoom siv no siv rau kev rho tawm los ntawm cov khoom siv hauv tsev precision siv CV rau 10 replicates, tus coefficient ntawm variation (CV, %) ntawm Ct tus nqi tsis ntau tshaj 10%.

Inter-batch sib txawv

Thaum cov khoom siv hauv tsev raug kuaj xyuas peb cov khoom siv hauv kev sim ntau lawm thaum rov muab rho tawm thiab, qhov sib txawv ntawm qhov sib txawv (CV, %) ntawm Ct tus nqi tsis ntau tshaj 10%.

Kev sib piv kev ua haujlwm

● Extraction efficiency piv

Kev sib piv kev ua tau zoo ntawm kev sib nqus hlaws thiab cov qauv tso tawm

concentration
luam / ml

magnetic hlaws txoj kev

tus qauv tso tawm

orfab

N

orfab

N

20000

28.01 Nws

28.76 Nws

28.6 ib

29.15 Nws

2000

31.53 Nws

31.9 ib

32.35 Nws

32.37 Nws

500

33.8 ib

34

35.25 Nws

35.9 ua

200

35.25 Nws

35.9 ua

35.83 ib

35.96 ib

100

36.99 ib

37.7 ib

38.13 Nws

undet

Qhov kev ua tau zoo ntawm cov qauv tso tawm tau zoo ib yam li txoj kev sib nqus hlaws, thiab qhov concentration ntawm cov kab mob tuaj yeem yog 200Copies / mL.

● CV tus nqi sib piv

Repeatability ntawm cov qauv tso tawm extraction

concentration: 5000Copies/ml

ORF1 ab

N

30.17 Nws

30.38 Nws

30.09 Nws

30.36 Nws

30.36 Nws

30.26 Nws

30.03 Nws

30.48 Nws

30.14 Nws

30.45 Nws

30.31 Nws

30.16 Nws

30.38 Nws

30.7 ib

30.72 ib

30.79 ib

CV

0.73%

0.69%

Thaum kuaj ntawm 5,000 daim / mL, CV ntawm orFab thiab N yog 0.73% thiab 0.69%, feem.

Macro & Micro-Test Sample Tso Reagent10

  • Yav dhau los:
  • Tom ntej:

  • Sau koj cov lus ntawm no thiab xa tuaj rau peb