Influenza A/B
Khoom npe
HWTS-RT003A Influenza A/B Nucleic Acid Detection Kit (Fluorescence PCR)
Kab mob sib kis
Influenza A tus kab mob yog ib qho kab mob ua pa nyuaj, muaj ntau hom kab mob xws li H1N1 thiab H3N2, uas muaj kev hloov pauv thiab tawg tawm thoob ntiaj teb.Antigenic hloov pauv yog hais txog kev hloov pauv ntawm tus kab mob khaub thuas A, ua rau muaj qhov tshwm sim ntawm tus kab mob tshiab.Cov kab mob khaub thuas B tau muab faib ua ob hom kab mob loj, Yamagata thiab Victoria.Cov kab mob khaub thuas B tsuas muaj cov tshuaj tiv thaiv kab mob, thiab lawv khiav tawm ntawm kev soj ntsuam thiab tshem tawm ntawm tib neeg lub cev tiv thaiv kab mob los ntawm lawv cov kev hloov pauv.Txawm li cas los xij, qhov kev hloov pauv ntawm tus kab mob khaub thuas B yog qeeb dua li tus kab mob khaub thuas A, thiab tus kab mob khaub thuas B kuj tuaj yeem ua rau tib neeg mob ua pa thiab ua rau muaj kev sib kis.
Channel
FAM | IFV A |
ROX | Internal Control |
VIC/HEX | IFV B |
Technical Parameters
Cia | ≤-18 ℃ |
Txee lub neej | 9 muaj |
Hom Qauv | oropharyngeal swb |
Ct | ≤ 28 |
CV | ≤ 5.0% |
LoD | IFV A: 500Copies/mL, IFV B: 500Copies/mL |
Qhov tshwj xeeb | 1. Cross-reactivity: there is no cross reactivity between this kit and adenovirus type 3, 7, human coronavirus SARSr-CoV, MERSr-CoV, HCoV-OC43, HCoV-229E, HCoV-HKU1, and HCoV-NL63, cytomegalovirus, enterovirus, parainfluenza virus, qhua pias virus, human metapneumovirus, mumps virus, respiratory syncytial virus type B, rhinovirus, bordetella pertussis, chlamydia pneumoniae, corynebacterium, escherichia coli, haemophilus influenzae, kab mob myocardial influencers mycoplasma pneumoniae, neisseria meningitidis , neisseria gonorrhoeae, pseudomonas aeruginosa, staphylococcus aureus, staphylococcus epidermidis, streptococcus pneumoniae, streptococcus pyogenes, streptococcus salivarius thiab human genomic DNA. 2. Kev ntsuam xyuas cuam tshuam: Cov tshuaj cuam tshuam raug xaiv los ntawm mucin (60mg / mL), tib neeg cov ntshav, oxymetazoline (2mg/mL), sulfur (10%), beclomethasone (20mg/mL), dexamethasone (20mg/mL), flunisolide ( 20μg/mL), triamcinolone (2mg/mL), budesonide (1mg/mL), mometasone (2mg/mL), fluticasone (2mg/mL), benzocaine (10%), menthol (10%), zanamivir (20mg/mL) ), azithromycin (1mg/L), cephalosporin (40μg/mL), mupirocin (20mg/mL), tobramycin (0.6mg/mL), oseltamivir phosphate (60ng/mL), ribavirin (10mg/L), thiab cov txiaj ntsig tau qhia. uas cuam tshuam cov tshuaj nrog cov concentrations saum toj no tsis muaj kev cuam tshuam cov tshuaj tiv thaiv rau kev tshawb pom ntawm cov khoom siv. |
Cov cuab yeej siv tau | Siv Biosystems 7500 Real-Time PCR System Siv Biosystems 7500 Fast Real-Time PCR Systems QuantStudio®5 Real-Time PCR Systems SLAN-96P Real-Time PCR Systems (Hongshi Medical Technology Co., Ltd.) LightCycler®480 Real-Time PCR system LineGene 9600 Plus Real-Time PCR Detection System (FQD-96A, Hangzhou Bioer thev naus laus zis) MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.) BioRad CFX96 Real-Time PCR System thiab BioRad CFX Opus 96 Real-Time PCR System |
Ua hauj lwm Flow
Kev xaiv 1.
Pom zoo muab rho tawm reagents: Macro & Micro-Test General DNA / RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (uas tuaj yeem siv nrog Macro & Micro-Test Tsis Siv Neeg Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) los ntawm Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Cov extraction yuav tsum tau ua raws li IFU.Lub extraction qauv ntim yog200 mL.Qhov pom zoo elution ntim yog 80μL.
Kev xaiv 2.
Pom zoo extraction reagents: Macro & Micro-Test Sample Release Reagent (HWTS-3005-8).Kev rho tawm yuav tsum tau ua raws li IFU.
Kev xaiv 3.
Pom zoo extraction reagents: Nucleic Acid Extraction lossis Purification Kit (YDP315-R).Kev rho tawm yuav tsum tau ua raws li IFU.Cov qauv rho tawm yog 140μL.Qhov pom zoo elution ntim yog 60μL.